INWERTER FALOWNIK 3-FAZOWY FoxESS T6 G3 (AFCI) 6kW
- Model: T6 G3
| Apparent power: | 6600 VA |
|---|---|
| Built-in display: | LCD |
| Connectivity: | Counter, E-stop, USB update, DRM |
| Cooling system: | Convection |
| Depth: | 183.5 mm |
| Efficiency: | 98.6% |
| Electromagnetic compatibility: | IEC 61000-6-1 /IEC 61000-6-2 /IEC 61000-6-3 /IEC61000-4-2/3/4/5/6/8 |
| Height: | 370 mm |
| Input current: | 14 / 14 A |
| Installation height (max): | 3000 m |
| International protection (ip) code: | IP65 |
| Island mode protection: | Y |
| Max. short circuit current of the module field: | 18.2 / 18.2 A |
| Maximum ac current: | 9.6 A |
| Maximum input power: | 9000 W |
| Maximum input voltage: | 1100 V |
| Monitoring of isolation: | Y |
| Monitoring of leakage current: | Y |
| Mppt voltage range: | 140 - 1000 V |
| Noise level: | 55 dB |
| Nominal ac current: | 8.7 A |
| Nominal ac power: | 6000 W |
| Nominal operating voltage: | 600 V |
| Number of mpp trackers: | 2 |
| Number of phases: | 3 |
| Operating relative humidity (h-h): | 0 - 100% |
| Operating temperature (t-t): | -25 - 60 °C |
| Output voltage: | 3/N/PE, 220V/380V, 230V/400V 240V/415V |
| Overcurrent protection: | Yes |
| Overvoltage protection: | Y |
| Overvoltage protection of ac output: | Y |
| Polarity reverse circuit protection: | Y |
| Power current type: | DC-to-AC |
| Power supply type: | Indoor/outdoor |
| Product colour: | White |
| Protection class: | 1 / AC: III; DC: ll |
| Purpose: | Solar panel |
| Quantity per pack: | 1 pc(s) |
| Rated mains frequency (hz): | 50/60, ±5 |
| Safety: | IEC 62109-1/2 |
| Short circuit protection: | Yes |
| Start-up voltage: | 140 V |
| Storage temperature (t-t): | -40 - 70 °C |
| Strings for mpp tracker: | 1+1 |
| Temperature protection: | Y |
| Topology: | Transformerless |
| Weight: | 17 kg |
| Width: | 480 mm |
Despite our best efforts, we cannot guarantee that the published technical data and photos do not contain inaccuracies or errors, which, however, cannot be a basis for claims.